How To Install A Condensate Drain Line
How to install a condensate drain line
Components of the condensate disposal system shall be cast iron, galvanized steel, copper, cross-linked polyethylene, polybutylene, polyethylene, ABS, CPVC, or PVC pipe or tubing.
How do you run an AC condensate drain line?
Connect the head of the garden hose to the opening of the condensate drain. Maintain a tight connection between the drain and the hose with your hand and run the hose on high in short bursts. This should allow the water to travel upwards and break up any clogs in the drain. Repeat step 2 until the water runs clear.
Can I use PVC for condensate drain?
PVC piping systems are recognized as acceptable for use in condensate drain systems in all major model plumbing codes.
Does a condensate drain need a vent?
no vent. per se, is required on the condensate line itself, unlike sanitary drains, which must be vented to prevent siphonage at the traps and possible collaspe of the sewer pipe due to possible negative pressures created when no vent is present.
What size should a condensate pipe be?
Internal condensate discharge pipework must be a minimum of 19mm ID (typically 22mm OD) plastic pipe or as per manufacturer's instructions and this should “fall” a minimum of 45mm per metre away from the boiler, taking the shortest practicable route to the termination point.
What is the normal pitch or slope for the condensate drain lines?
1. Slope - The drain shall have a slope of not less than 1/8 inch per foot and shall be approved corrosion resistant pipe not less in size than 3/4 of an inch for air cooling coils and not less than the drain outlet size for evaporative coolers or other equipment.
Where do I route my AC condensate drain line?
A condensate drain line usually goes from your unit indoors to the outdoors near your air conditioner's external unit. The pipe connected to the exterior of your home is where the drain line ends. In contrast, the capped pipe beside or near your indoor AC unit is the condensate drain access point.
Where should an AC condensate line drain to?
In newer homes, HVAC condensate drains are tied most often to bathroom drains. Common drain lines inside your home include in your bathrooms (sinks, shower or tub, toilet), kitchen (sink, water line to your freezer), laundry room, and water heater.
What is code for AC drain line?
2021 CODE: 307.2. Condensate drains shall not directly connect to any plumbing drain, waste or vent pipe. Con- densate drains shall not discharge into a plumbing fixture other than a floor sink, floor drain, trench drain, mop sink, hub drain, standpipe, util- ity sink or laundry sink.
What size PVC pipe is used for AC drain?
The AC drain line should be located near the outside unit, leading from your AC unit's evaporator coil. It is typically a ¾ inch PVC pipe – however some drain lines may be copper.
Can you use copper pipe for condensate?
Everyone knows that copper tube has a proven history in use in a variety of applications, however a common question is "can I use copper tube in a steam system?" Just like in water systems, copper tube has long been used in both steam and steam condensate piping systems.
Can you drain AC condensate into sewer?
Different municipalities may require condensate be disposed of to the sanitary sewer, while others may require disposal to building exterior or storm drainage piping. Some AHJ may even require the use of additional equipment to neutralize certain elements/compounds prior to disposing of the condensate.
How deep should a condensate drain trap be?
If a unit were to be operating at minus 6 inches WC maximum negative plenum pressure then the trap height, per the guidelines shown in Figure 1a, requires 7 + 3½ + 1½ + 1 inches of height from under the floor or about 13 inches below the floor level.
Why does a condensate line need a trap?
Condensate drains typically have traps, which are designed to keep air from moving in or out of the air handler without preventing condensate drainage. The absence of a properly working p-trap could push unfiltered air into your home and cause an overflow of the condensate drain.
Can condensate drain to ground?
The most popular areas we terminate condensate drain lines to is the side of the house and usually about six inches from the ground. And this can be in a planted area that is large enough to accept the amount of drainage, and soak down into the earth.
Can you run a condensate pipe outside?
It is possible to terminate a condensate pipe into a rain water down pipe that terminates into the foul waste system. As with all externally-run condensate pipes, it is recommended to keep the external run to minimum and the pipe diameter to 32mm when exiting the property.
Should condensate pipe be insulated?
For other gas or oil boilers then external condensate runs must be kept to a maximum of 3 metres and must be insulated. It may also be advisable to increase the pipe diameter to 32mm. If pipework is not sufficiently sized and insulated, freezing of the condensate may occur.
How much water should be coming out of a condensate pipe?
Your air conditioner should naturally drain water that was once humidity out of your home. On average, you can expect 5 to 20 gallons of condensate per day. If water is not draining, your climate may be too dry or your system is not functioning properly.
How far should condensate line be from house?
The most experienced inspectors recommend that the a/c condensate be routed no less than 12 inches from the foundation wall to avoid long term implications.
How much drop does a drain line need?
But do you know the proper slope? The ideal slope of any drain line is ¼ inch per foot of pipe. In other words, for every foot the pipe travels horizontally, it should be dropping ¼ inch vertically.